System #5 : System is fully functional. Tested system in both heat and
Removed and installed new Rheem gas furnace with 3.5 ton a/c unit and 4 ton evaporator coil for upstairs. Installed new return plenum with 20x25x4 filter, new emergency drain pan, new pan safety switch, new coil safety switch and new composite pad for outdoor unit. Reconnected supply plenum, all return ducts, high voltage, low voltage, drain line, gas line and vent pipe. Tested system operations, set proper charge. Removed and installed new Rheem gas furnace for left side of main level. Installed new emergency drain pan, new pan, safety switch, new coil safety switch, new condensation pump, and new media filter cabinet box with 20x25x4 filter. Tested system operations.
Upstairs Returns - 10, 12, 10, 8 Upstairs Supplies - 8, 12, 10, 10 Main Foor Return - 10, 10, 12
#4 : Drain line cleared and repaired, condensate pump moved into the drain pan and water vacuumed from the drain pan. Replaced inoperable float safety switch. Washed outdoor coils and added 3 pounds of R410 Refrigerant. System is fully functional and operating within manufacturer specifications. Refrigerant pressures and temperature are appropriate for indoor and outdoor conditions. Temp split of 19 degrees. #3 : Washed outdoor coils and replaced filter. System has an underline air flow issue, not enough duct work. System is performing as best as it can at this time. System has a 19 degree temperature split. Need to return to get #5 running. Still need to replace filter in #4 and cross reference air handler model number for proper filter size.
#1 furnace 29 years old - dirty filter - blower runs #1 coil r22 19 years old - no inline drain #1 air conditioner r22 - 17 years old - compressor pulling lock rotor amps of 100.5 (system needs replacing), low voltage chewed through and capacitor just hanging #2 furnace 29 years old - no filter installed - sever rusting on burner compartment #2 coil 410a - 6 years old #2 air conditioner 410a - 6 years old - TXV - low sub cool possibly from dirty blower, dirty coil, low airflow, low on charge #3 furnace 6 years old #3 coil 410a 6 years old - filter dirty - blower runs #3 air conditioner 410a 6 years old needs - low air flow or low on charge #4 air handler 6 years old - no filter installed - water in safety pan - aux switch removed - kinked drain (pump plastic and or bad condensate pump #4 heat pump 410a 3 years old? Low on refrigerant #5 air handler 5 years old - electrical disconnect melted #5 heat pump 6 years old 410a - refrigerant in outdoor unit - power off due to air
Cleared drain line under warranty
Relocated thermostat, unit operating properly
Checked unit,pressures,sh sc delta t, system operating properly. Recommend moving thermostat from front by windows, it is picking up heat from sun shining through, please give quote on moving
DCM1: AC complete, replaced (1) 16x25x1 filter. System is fully functional and operating within manufacturer specifications at this time. Refrigerant pressures and temperatures are appropriate for outdoor and indoor weather conditions. Noticed partial clogg in drain line blew through with nitrogen. Drain line is draining at this time.