Unit had bad dual capacitor, replaced, operating properly
DCM1: A/C complete, replaced (1) 16x25x1 filter. System is fully functional and operating within manufacturer specifications at this time. Refrigerant pressures and temperatures are appropriate for indoor and outdoor weather conditions. Temp split 16*. Photos and maintenance checklist attached.
DCM1: AC complete, replaced (1) 24x24x1 filter. System is fully functional and operating within manufacturer specifications at this time. Refrigerant pressures and temperatures are appropriate for indoor and outdoor weather conditions. Temperature split 17*. Photos and maintenance checklist attached.
DCM1 : A/C complete, replaced (1) 14x25x1 filter. System is fully functional and operating within manufacturer specifications at this time. Refrigerant pressures and temperatures are appropriate for indoor and outdoor weather conditions. Temperature split 16*. Photos and maintenance checklist attached. Filter was impacted, recommend replacing filter more frequently to help with longevity of the system.
Did spm, system operating properly, installed condensation safety in line with drain because it had no water safety., found 35+5mfd dual capacitor on condenser weak on the compressor side. The owner chose to not replace at this time. I gave her a estimate.
DCM1.5: AC complete, replaced (2) 14x20x1 filters and washed mini split filters. System is fully functional and operating within manufacturer specifications at this time. Refrigerant pressures and temperatures are appropriate for outdoor and indoor weather conditions. Temp split 17. Photos and maintenance checklist attached.
DCM1 service 1 of 2 AC completed changed (1) 16x25x1 filter, tested system operation’s everything is operating properly at this time attached is Ac maintenance checklist.
DCM2 service 2 of 2 Heat: Changed (1) 16x20x1 filter,, Performed Heating Maintenance Per checklist, tenant mentioned on arrival that the system would not go into cool mode and would only blow hot air, after checking operation found that the thermostat was not sending 24v to the reversing valve, recommended to replace thermostat homeowner said that she has a spare nest thermostat that they will try first.
DCM 1 :Service 2 of 2 ; Heat, Changed 16x20x1, Performed Heating Maintenance Per Checklist, System is Running at this time.
DCM2 service 1 of 2 Heat completed changed (2) 14x20x1 washed mini split filters, tested system operation’s everything is operating properly at this time attached is Heat maintenance checklist.