Jonesboro Heating and Air

Let Dobbs Heating and Air be your only stop for all of your Jonesboro Heating and Air Repair, Replacement, or Installation needs. Call today for your free estimate!

Local Reviews
for Jonesboro, GA


Rob  S.

Rob S.

Arrived to No Cool on upstairs system Identified faulty thermostat, homeowner had installed batteries backwards. Energized and tested system. System is almost completely out of R22 refrigerant.Little to no heat transfer is occurring within the system. Suction side is pulling into a vacuum. Homeowner request quote for replacement. In addition, downstairs system hasn’t cooled for an unknown period of time

Near Washington Dr, Jonesboro, GA 30238
Rob  S.

Rob S.

Replaced outdoor 3 pole contactor. Tested system. System is low on refrigerant, approximately 4 to 6 pounds of R22. System will freeze if allowed to run. Diagnostics photo attached. Unknown how long system has been running with low refrigerant levels. Amp draw is low and superheat is high, which are both symptoms of a system running with low refrigerant levels. The compressor sounds like it’s been running with low refrigerant levels for a significant period of time. I initially thought the compressor was running backwards due to the vibrations and sounds of the system running. Checked to ensure voltage was in phase and it was. System is an R22 unit from 2007. Possibility of total compressor failure after adding refrigerant is high. Factory charge of unit is 10 pounds with an additional 1-2 pounds to account for line set and evaporator Due to cost of R22 refrigerant and likelihood of future part failure, recommend system replacement

Near Tara Blvd, Jonesboro, GA 30236
Rob  S.

Rob S.

Arrived to No Cool Identified faulty 3 amp fuse on control board. 3 amp fuse is faulting due to outdoor contactor failure. Video attached. Need to replace 3 pole contactor. Estimate included Outdoor unit disconnect off at outdoor unit Indoor unit off at Breaker #8

Near Tara Blvd, Jonesboro, GA 30236
Keith D.

Keith D.

Quoted in hvacbizpro and emailed

Near Deer Crossing Way, Jonesboro, GA 30236
Rob  S.

Rob S.

Arrived to No Cool System has multiple issues 1. Evaporator drain pan is rusted to the point water is leaking down furnace and into emergency drain pan 2. Emergency drain pan has had drain connector destroyed and no longer has a drain. This is the location that water that is leaking into emergency pan is leaking onto ceiling 3. Blower motor is extremely dirty causing low airflow 4. System is overcharged with R22 refrigerant. More than likely, the system was freezing due to low airflow so refrigerant was added to prevent this freezing Photos attached

Near Deer Crossing Way, Jonesboro, GA 30236

"Great Customer Service and Follow Up"

5 stars
“The service I received from Dobbs was A-1. From the initial call, scheduling and end of service follow through, I received great communication and service. I was informed about the work needed, costs and there were no surprises! I am a very satisfied customer.”

"Great Company, Great Service!"

5 stars
“I have had nothing but great experiences with Dobbs Heating and Air. They do great work, give great advice, and make sure all your questions and concerns are answered. I definitely recommend them!”

"Impressed by Dobbs’ professionalism"

5 stars
“I have been so impressed by Dobbs’ professionalism and service! Thank you for keeping us cool in the summer and warm in the winter!”
~ Jacqueline Hudson, Satisfied Customer

"John was great"

5 stars
"John was great. I use DOBBS for both my business and home and would not trust anyone else with my HVAC needs.”
~ Jeremy Commins, Satisfied Customer

"Friendly, Courteous, and Knowledgeable"

5 stars
"Always friendly, courteous, and knowledgeable. I appreciate their prompt arrival or phone call if there is a delay.”
~ Lisa, Satisfied Customer