DCM1 complete; AC; (2) F14141 replaced. System is fully functional. All components are operating within manufacturer specifications. Refrigerant pressures and temperatures are appropriate for indoor and outdoor conditions. AC checklist attached. Diagnostics photos attached
DCM1 complete; AC; (2) F14141 replaced. System is fully functional. All components are operating within manufacturers specifications. Refrigerant pressures and temperatures slightly higher than expected for indoor and outdoor temperatures. AC checklist attached. Diagnostics photos attached. System is slightly overcharged. Due to age of equipment ( 19 years ) would recommend to continue monitoring system.
DCM1 complete; AC; (2) F14141 replaced. System is fully functional. All components are operating within manufacturer specifications. Refrigerant pressures and temperatures are appropriate for indoor and outdoor conditions. AC checklist attached. Diagnostics photos attached.
Arrived to Gloria Wade Tenant was struggling to understand functions on thermostat. I reprogrammed the thermostat and reconfigured the existing schedule to meet her comfort needs. Tested system, has a 34* heat rise. Took the conditioned space from 74 to 79during the testing procedure.
DCM1 complete; Heat; (2) F14141 replaced. System is fully functional. All components are operating within manufacturer specifications. Gas pressure and temperature rise are within design parameters. Heat checklist attached. Dryer vent has separated and is starting to cover crawlspace with lint. Photo attached Bathroom sink has a leak and is leaking into crawlspace. Photo attached
Spoke to tenant no complaints of heating, call should’ve been assigned to Gloria Wade.
DCM1 complete; Heat; (2) F14141 replaced. System is functional. Refrigerant pressure on high side is elevated. Blower wheel is dirty, low airflow can lead to increased high side pressure. Blower motor has been replaced. Ductwork appears to be adequate, return in (2) 12 in to a 14. System is 18 years old. System could be slightly overcharged with refrigerant. System is producing 114* at supply duct. Continue to monitor through semi-annual maintenance
DCM1 complete; Heat; (2) F14141 replaced. System is functional. Components are operating within manufacturer specifications. Refrigerant pressures and temperatures are appropriate for indoor and outdoor conditions. Heat checklist attached.
Unable to complete, no key located in lockbox