Customers say: The reviews exhibit a positive sentiment overall, with a slight inclination towards the positive. The technicians are described as knowledgeable, respectful, and helpful, providing clear explanations and addressing concerns. Customers appreciate the professionalism, efficiency, and politeness of the Dobbs team. Positive reviews highlight the quality of work, timely responses, and fair pricing. Customers express satisfaction with the services provided, mentioning the technicians' expertise, thoroughness, and ability to explain technical information in a way that is easy to understand. The positive reviews also mention the company's reliability, punctuality, and willingness to go the extra mile to ensure customer satisfaction. However, there are a few negative reviews that mention high costs and a perception of being overcharged. Additionally, some customers express dissatisfaction with the length of time taken to complete the work or the quality of the workmanship. Overall, the reviews suggest that Dobbs provides reliable and efficient HVAC services, with a focus on customer satisfaction and technical expertise. While there are some areas for improvement, the positive reviews outweigh the negative ones, indicating that Dobbs is a reputable and trustworthy company in the HVAC industry.
DCM2: AC complete, replaced (2) 16x25x1 filters. Both systems are operating at this time and refrigerant pressures and temperatures are appropriate for indoor and outdoor weather conditions. Found indoor capacitor out of tolerance on apartment system, replaced capacitor and tested capacitor is now operating within manufacturer specifications. System is R22 due to age of equipment multiple part failure is possible.
Warranty Description - Dobbs Club Member 2 Year Part and Labor Non Club Member 1 Year Part and Labor Commercial 1 Year Part and Labor Replaced relay, unit operating properly
Completed single system cooling maintenance. Operating properly at this time. Replaced filter
Could not complete maintenance on RTU #1 due to bad cooling relay, needs replacing. Also replaced a high voltage fuse in disconnect box. Also it needs 2 more 16x20x2 filters when we return. Pictures included. Completed cooling maintenance on RTU #2 and #3. Both operating properly at this time.replaced filters. RTU #2 is a very old R22. I recommend replacing.
DCM2 complete; Heat; (2) F16251 replaced. Systems are fully functional. All components are operating within manufacturer specifications. Gas pressures and temperature rise are within design tolerances. Heat checklist attached
DCM1: A/C complete, replaced (1) 16x20x1 filter. System is fully functional and operating within manufacturer specifications at this time. Refrigerant pressures and temperatures are appropriate for indoor and outdoor weather conditions. Temp split 17*. Photos and maintenance checklist attached.
Arrived to no cool condenser fan motor was running but compressor was reading 0 amps. Tested 30+5 capacitor it was reading 0 and replaced it. Checked indoor temperature split was 17 degrees between return and supply. Refrigerant pressures were appropriate, system functions as designed.
Replaced all registers and cleaned out dryer vent
Removed old equipment and installed new Rheem 14 seer 3.5 ton full gas system. Installed new return plenum with 20x25x1 filter, new emergency drain pan, new pan safety switch, new coil safety switch, new composite pad for outdoor unit and new surge protector. Reconnected supply plenum return box, high voltage, low voltage, drain line, gas line, and vent pipe. Tested system operations in heating and cooling, set proper charge.
Quoted new furnace and air conditioner