McDonough Heating and Air

Let Dobbs Heating and Air be your only stop for all of your McDonough Heating and Air Repair, Replacement, or Installation needs. Call today for your free estimate!

Local Reviews
for McDonough, GA

Dobbs Heating and Air Rated 5.0 out of 5 stars based on 2 customer reviews

Map of McDonough, GA 30253

Great and friendly service




Review of Dobbs Heating and Air

McDonoughGA30253 33.4825-84.2225

Map of McDonough, GA 30253

NIce




Review of Dobbs Heating and Air

Khalil was very nice and fast. He is good at his job.

McDonoughGA30253 33.4375-84.1675

Rob  S.

Rob S.

Replaced 3 amp low-voltage fuses on systems 4, 5 and 6. Tested systems, functions as designed.

Near Jodeco Rd, McDonough, GA 30253
Rob  S.

Rob S.

Confirmed proper operation of all installed defrost control boards, systems are operating within manufacturer design at this time. Noticed thermostats have been moved off schedule and to a lower heat temperature roughly 60*-61* by someone other than Dobbs.

Near Jodeco Rd, McDonough, GA 30253
Brad  N.

Brad N.

Returned to replace pump plastic that was chewed up by rodents and leaking inside of G building, ran a new line from pump to outside and secured to the line set tested pump and system is draining properly at this time.

Near Jodeco Rd, McDonough, GA 30253
Rob  S.

Rob S.

Arrived to No Cool Building G, System #8, plastic condensate line has been compromised, water when pumped through condensate pump is leaking into adjacent unit. Need to contact the owners of that unit so a repair can be made to the pump plastic. Building N, System #11, reset breaker, possibly tripped from recent storms and tested system. Functions as designed .

Near Jodeco Rd, McDonough, GA 30253
Rob  S.

Rob S.

Cleared drain pan and drain line. Installed new water safety and tested. System is cooling as designed.

Near Eddie Craig Ct, McDonough, GA 30252
Rob  S.

Rob S.

Replaced existing transformer, disconnected both high and low voltage. Installed new transformer, wired in high voltage, wired in low voltage and installed 5 amp fuse to protect the transformer. Tested system. Found tree growing out of outdoor unit. Removed tree and tested again, system is cooling. System is 23 years old.

Near Eddie Craig Ct, McDonough, GA 30252
Rob  S.

Rob S.

Main Floor Unit: Identified clogged drain at drain pan, photo attached. Identified fail pan safety switch, photo attached Bonus Room : Identified thermostat was off, diagnosed failed transformer Estimates to repair attached

Near Eddie Craig Ct, McDonough, GA 30252
Rob  S.

Rob S.

Identified clogged drain on AHU #1. Drain line has larvae in it. Cleared the other drain line beside it. Wasn’t clogged but wanted to ensure no larvae were beginning to clog it

Near McDonough Pkwy, McDonough, GA 30253
Rob  S.

Rob S.

Cleaned blower wheel, housing and motor. BLOWER MOTOR COULD FAIL AT ANY MOMENT. System is currently operational, observed fan operation for over 20 minutes while cleaning up and writing invoice and fan continued to perform as designed. Operational amp draw is elevated on blower motor 5.9 / 6.8 but below listed RLA. Fan and blower were extremely dirty, parts of a filter were found in the wheel. Cleaned with detergent and brushed dry the motor and blew dust out with air compressor. Photos attached.

Near Autumn Leaf Dr, McDonough, GA 30253
Rob  S.

Rob S.

2nd Floor : furnace tagged as failure to cycle. Tightened flame sensor bracket. Tested system 3 times, system functioned each time. Heat rise is 25-55*, current heat rise 30*. Diagnostics attached. Tested for leaks with electronic and micro-bubble leak detectors. No leaks identified. Filter was dirty. Filters are undersized for system capacity. 1st Floor : System had exposed ice at piston and frosting at drain line port. Furnace fan motor and blower wheel are extremely dirty. Fan is binding and failing to turn, witnessed this occur twice while I was working on 2nd floor furnace. System will freeze if allowed to operate. System turned off at thermostat. Both systems are drained into singular condensate pump. Condensate pump is not wired into either systems low voltage. iIn the event of condensate pump failure, the systems will continue to operate and water damage will occur to the second floor ceiling.

Near Autumn Leaf Dr, McDonough, GA 30253

"Great Customer Service and Follow Up"

5 stars
“The service I received from Dobbs was A-1. From the initial call, scheduling and end of service follow through, I received great communication and service. I was informed about the work needed, costs and there were no surprises! I am a very satisfied customer.”

"Great Company, Great Service!"

5 stars
“I have had nothing but great experiences with Dobbs Heating and Air. They do great work, give great advice, and make sure all your questions and concerns are answered. I definitely recommend them!”

"Impressed by Dobbs’ professionalism"

5 stars
“I have been so impressed by Dobbs’ professionalism and service! Thank you for keeping us cool in the summer and warm in the winter!”
~ Jacqueline Hudson, Satisfied Customer

"John was great"

5 stars
"John was great. I use DOBBS for both my business and home and would not trust anyone else with my HVAC needs.”
~ Jeremy Commins, Satisfied Customer

"Friendly, Courteous, and Knowledgeable"

5 stars
"Always friendly, courteous, and knowledgeable. I appreciate their prompt arrival or phone call if there is a delay.”